Setting up NIC Policies: if uplink is down, veths can still be up based on the policy
But failover won’t work.
Available from 1.0.2d
Set this to all the service profile which u don’t want failover to work , but want the link to stay up when uplink fails.
Test
Linux Suse on Server 5 – eth0 – which corresponds vnic1 on Fabric B.
Redhat 5.4 on Server 3 eth0 – which corresponds to vnic1 on Fabric
Able ping router via uplink and ping the redhat linux (6120 switches within)
Let us bringdown the uplink
Able to ping the linux but not the router.
(I shutdown both uplinks still able to ping between the servers)
Config change
UCS1-FI-B(nxos)# show run int veth767
version 4.0(1a)N2(1.2e)
interface vethernet767
no cdp enable
switchport trunk allowed vlan 1,143,153,163
bind interface Ethernet1/1/4
no pinning server sticky
pinning server pinning-failure link-down
UCS1-FI-B(nxos)# show run int veth788
version 4.0(1a)N2(1.2e)
interface vethernet788
no cdp enable
switchport trunk allowed vlan 1,143,153,163
bind interface Ethernet1/1/5
no pinning server sticky <<<<<<<<<<<<<<<<<<<<<<<
UCS1-FI-B(nxos)# show int br | inc veth
veth767 1 eth trunk down inactive 10G(S) -- <<<no change of policy
veth775 1 eth trunk up none 10G(S) – esc-no-uplink – veth stays up
veth788 1 eth trunk up none 10G(S) --
veth790 1 eth trunk up none 10G(S) --
No comments:
Post a Comment